The Tokyo Keiki UFL-30 clamp-on ultrasonic flow meter

Main features of the UFL-30R ultrasonic flow meterUltrasonic-flowmeter-UFL-30R

Transit times of ultrasonic pulses transmitted in a liquid vary with the flow velocity of the liquid and ultrasonic flow meters utilize this characteristic to measure flow.

Regardless of whether the liquid is electrically conductive or non-conductive, ultrasonic flow meters can measure various types of liquids such as potable water, river water, industrial water, agricultural water, wastewater, seawater and pure water.

Transducers are clamped on to the outside of the pipe so it is not necessary to cut pipes or stop flow for installation and there is no pressure loss.

Flow measurements are possible over a wide range of -30m/s to +30m/s.

Economical measurements of flow from 25mm to 6000mm can be obtained.

PC configuration software allows for easy operation. The graphical user interface allows anyone to input data. 

Technical specification

Connection to PC enables setting of flowmeter unit,setting menu and reading of measurement values andoperation status

Overall specifications

Measured fluids Homogeneous and sonically conductive fluids
Temperature range -20°C to +115°C (depend on transducer)
Turbidity 10000 mg/L or less
Material of pipes Materials which allow for the stable transit of ultrasonic waves such as
steel, SUS, castings, ductile casting, PVC, FRPM, etc.
Diameters DN25mm to DN600mm
Lining None, tar epoxy, mortar, etc.
Measurement range Converted to flow velocity: -30 m/s to +30 m/s
Measurement cycle 60 ms
Measurementmethod Ultrasonic pulse transit time difference method

Measurement Performance

Measurement accuracy D≧300mm, ±1% of reading, however ±0.008m/s for velocities less than 0.8m/s
D<300mm, ±1% of reading, however ±0.02m/s for velocities less than 2m/s
Repeatability ±0.5%
Range ability 1 : 300

Communications and outputs

Analog output 2 outputs, Instantaneous flow rate, 4 - 20mA
Pulse output 4 channel, DC48V, 0,4A, insulated photo coupler
Digital output RS232 One-way output mode
Following data is output per set output cycle
Instantaneous flow rate, forward/backward flow totalized
value and various warnings (flow meter mode: linear flow
rate and various warnings)
Intercommunication mode
The flow meter is set via a PC connection, with a main menu, measurement reading values and operating status
Data setting PC connected to Digital Output port 2, setting through PC
with configuration software (LCD 4-keys entry is
available, but limited)

 

Downloads

Catalogues
icon Clamp-on Ultrasonic Flowmeter UFL-30 (324.01 kB)
icon Product Sheet Clamp-on Flow Meter UFL-30 (1.43 MB)
Manuals